= SDL_hid_read = Read an Input report from a HID device. == Syntax == int SDL_hid_read(SDL_hid_device *dev, unsigned char *data, size_t length); == Function Parameters == {| |'''dev''' |A device handle returned from [[SDL_hid_open]](). |- |'''data''' |A buffer to put the read data into. |- |'''length''' |The number of bytes to read. For devices with multiple reports, make sure to read an extra byte for the report number. |} == Return Value == Returns the actual number of bytes read and -1 on error. If no packet was available to be read and the handle is in non-blocking mode, this function returns 0. == Remarks == Input reports are returned to the host through the INTERRUPT IN endpoint. The first byte will contain the Report number if the device uses numbered reports. == Version == This function is available since SDL 2.0.18. ---- [[CategoryAPI]]